1.
The Journal of Clinical Anesthesiology ; (12): 267-270, 2018.
Article in Chinese | WPRIM | ID: wpr-694927

ABSTRACT

Objective To explore the feasibility of FloTrac/Vigileo System in hemodynamic monitoring during the surgery of single-lung ventilation patients.Methods Twenty-five patients with thoracoscopic lobectomy under general anesthesia,aged 35-65 years,ASA physical status Ⅰ or Ⅱ, preoperative showed no application taboo of FloTrac/Vigileo system or transesophageal echocardio-graphy (TEE).The radial artery puncture catheter was inserted after getting into the operating room, then connect the FloTrac/Vigileo system,after that the TEE was inserted following the induction of general anesthesia.Using the FloTrac/Vigileo system to record the stroke volume (SVF),cardiac output (COF),stroke volume variation (SVV),at the moment of after turning over (T0),opening chest and single-lung ventilation(T1),single-lung ventilation for 15 minutes (T2),single-lung venti-lation for 30 minutes (T3),single-lung ventilation for 45 minutes (T4)single-lung ventilation for 60 minutes (T5).Using TEE to monitor the index and record the the stroke volume (SVT)cardiac out-put(COT)and inferior vena cava collapse index(cIVC)of the same patient at same time as Group F. Results There was no statistically significant different between SVFand SVTat T0-T5in both groups,Overall correlation analysis,r=0.84,P<0.01.There is no statistically significant different between COFand COTat T0-T5in both groups,Overall correlation analysis,r=0.92,P<0.01. Correlation analysis of SVV of group F and cIVC of group T,the results were positively correlate,r=0.80,P<0.01.Conclusion FloTrac/Vigileo system can be used as a monitoring method for mo-nitoring hemodynamics in thoracic surgery.

2.
Chongqing Medicine ; (36): 4348-4349, 2017.
Article in Chinese | WPRIM | ID: wpr-667624

ABSTRACT

Objective To investigate the effect of different operation positions on cardiac index (CI) and stroke volume variation (SVV) in the patients monitored by FloTrac/Vigileo system to provide some references for the hemodynamic management and liquid treatment of the patients.Methods Sixty patients scheduled for elective TV auxiliary thoracoscope radical operation of esophageal cancer.The CI and SVV changes were observed by using the FloTrac/Vigileo system.CI,SVV and CVP were recorded at 5 min after anesthesia induction (T0),5 min after converting to the position of head low feet high (T1),5 min after converting to the position of head high feet low (T2).Results Compared with T0,CI at T1 and T2 was decreased(P<0.05);compared with T0,SVV at T1 was decreased and CVP was increased;SVV at T2 was increased and CVP was decreased(P<0.05).Conclusion The operation position change may have a significant impact on the patient's CI,SVV and CVP.Focusing on the corresponding change can provide some references for the intraoperative hemodynamic management and liquid treatment.

3.
Tianjin Medical Journal ; (12): 294-296, 2017.
Article in Chinese | WPRIM | ID: wpr-510477

ABSTRACT

Objective To investigate the effects of different values of PEEP on cardiac index (CI), stroke volume variation (SVV) and oxygen transport index (DO2I) in patients monitored by FloTrac/Vigileo system, and to provide some references for the hemodynamic management and improvement of oxygenation for patients. Methods Sixty patients scheduled for elective television (TV) auxiliary thoracoscope radical operation for esophageal cancer were included in this study. Data of CI, SVV and DO2I were observed by the FloTrac/Vigileo system. Changes of CI, SVV and DO2I were recorded after anesthesia induction and turn left side (T0), artificial pneumothorax with 0 PEEP after 5 minutes (T1), artificial pneumothorax with 5 PEEP after 5 minutes (T2), artificial pneumothorax with 10 PEEP after 5 minutes (T3), and artificial pneumothorax with 15 PEEP after 5 minutes (T4). Results Compared with T0, CI decreased and SVV increased significantly at T1, T2, T3 and T4(P<0.05). Compared with T1, CI decreased and SVV increased at T4. DO2I increased at T2 and T3 compared with that of T1(P<0.05). Conclusion PEEP may have a certain influence on CI and SVV in the process of operation. The values of 5-10 PEEP can significantly improve oxygenation and have a less influence on hemodynamics, which can be appropriately used in clinical care.

4.
Chinese Journal of Anesthesiology ; (12): 78-80, 2014.
Article in Chinese | WPRIM | ID: wpr-470756

ABSTRACT

Objective To determine if the cardiac index (Cl) measured with FloTrac-Vigileo system agrees with that measured with pulmonary artery catheter (PAC).Methods Forty-three ASA Ⅱ or Ⅲ patients aged 53-75 yr weighing 46-100 kg undergoing off-pump coronary artery bypass grafting were included in this study.Anesthesia was induced with midazolam,sufentanil,propofol and rocuronium and maintained with propofol,remifentanil and atracurium.One MAC sevoflurane was inhaled at breast bone splitting and closing.Cl was measured with FloTrac-Vigileo system and PAC before,and at 5,15 min of sevoflurane inhalation and recorded.All data were compared by Bland-Altman analysis and with kappa coefficient for agreement and percentage error was calculated.Results Bland-Altman comparison of FloTrac-Vigileo system and PAC:matching data of 258 measurements:Cl (2.8 ± 0.6) L·min-1 ·m-2,bias was 0.23 L·min-1 ·m-2 and limit of agreement was (-0.57,1.02) L·min-1 ·m-2,resulting in κ =0.546 and an overall percentage error of 28.6%.Conclusion Cl values obtained by FloTrac-Vigileo system agrees well with that obtained by thermodilution technique using PAC in patients undergoing off-pump coronary artery bypass grafting.

5.
The Journal of Clinical Anesthesiology ; (12): 1169-1171, 2014.
Article in Chinese | WPRIM | ID: wpr-457758

ABSTRACT

Objective To investigate the effect of the different position on hemodynamic moni-tored by FloTrac/Vigileo system in patients undergoing laparoscopic appendectomy.Methods Sixty patients undergoing laparoscopic appendectomy,ASA Ⅰ or Ⅱ,were randomly divided into three groups (n=20):group A,B and C underwent the trendelenburg position of 10 degrees,20 degrees and 30 degrees,respectively.HR,MAP,cardiac output (CO),cardiac index (CI)and stroke volume (SV)were recorded before pneumoperitoneum (T0 ),1 min after pneumoperitoneum (T1 ),5 min af-ter trendelenburg position (T2 ),20 min after pneumoperitoneum (T3 ),1 min after the end of pneu-moperitoneum (T4 )and 5 min after the end of trendelenburg position (T5 )after induction of anesthe-sia.The time of pneumoperitoneum and operation was recorded.Results Compared with T0 ,HR and MAP increased significantly at T1-T3 in three groups(P<0.05);Compared with group C,CO and SV decreased significantly at T2-T3 in group A and group B (P<0.05).Compared with T1 ,CO and SV increased at T2-T3 in group C (P<0.05).Compared with group C,the time of pneumoperitoneum and operation was longer in group A and B (P<0.05).Conclusion During the operation of laparo-scopic appendectomy,the change of the hemodynamic is in clinical safe range,and the time of pneu-moperitoneum and operation is shorter in the position of 30°than 10°and 20°in laparoscopic appen-dectomy.

6.
Chinese Journal of Anesthesiology ; (12): 958-960, 2011.
Article in Chinese | WPRIM | ID: wpr-422406

ABSTRACT

ObjectiveTo determine ff the cardiac index (CI) measured with FloTrac-Vigileo system agrees with that measured with pulmonary artery catheter (PAC).MethodsForty-three ASA Ⅱ or Ⅲ patients aged 53-75 yr weighing 46-100 kg undergoing off-pump coronary artery bypass grafting were included in this study.Anesthesia was induced with midasolam,sufentunil,propofol and rocuronium and maintained with propofol,remifentanil and atracurium.One MAC sevoflurane was inhaled at breast bone splitting and closing.CI was measured with FloTrac-Vigileo system and PAC before,and at 5,15 min of sevoflurane inhalation and recorded.All data were compared by Bland-Altman analysis and with kappa coefficient for agreement and percentage error was calculated.ResultsBland-Altman comparison of FloTrac-Vigileo system and PAC:matching data of 258 measurements:CI (2.8 ± 0.6 ) L· min - 1 · m- 2,bias was 0.23 L* min- 1 · m - 2 and limit of agreement was ( - 0.57,1.02)L · min- 1 · m- 2,resulting in κ = 0.546 and an overall percentage error of 28.6 %.ConclusionCI values obtained by FloTrac-Vigileo system agrees well with that obtained by thermodilution technique using PAC in patients undergoing off-pump coronary artery bypass grafting.